Offering camera control, image streaming over Ethernet, analytics, and raw data collection, the Teledyne FLIR A50 Image Streaming Automation Thermal Camera is a lightweight, small, fixed-focus, infrared-imaging automation camera. Delivering detailed, low-noise thermal imaging with embedded temperature data, the Teledyne FLIR A50 Image Streaming Automation Thermal Camera has a 464 x 348px IR resolution, -20°C to +1000°C temperature range, and ±2°C/2% accuracy. Temperature linear mode and 16-bit image streaming allow temperature readings to be extracted from each pixel. Designed to withstand harsh environments (IP66-rated) and fitted with heavy-duty M8/12 connectors, the Teledyne FLIR A50 Image Streaming Automation Thermal Camera is easy to install. It is also easy to integrate. The Teledyne FLIR A50 Image Streaming Automation Thermal Camera is GigE Vision and GenICam compliant; includes an SNMP trap and advanced firewall protection; and can be easily configured via a web browser. The Teledyne FLIR A50 Image Streaming Automation Thermal Camera is a flexible, reliable, durable, temperature-measuring automation camera perfect for optimising process and quality control; improving yield and through-put time; and lowering costs.
Digital I/O connector type | M12 12-pin A-coded, Male (shared with external power) |
Digital Inputs | 2x opto-isolated, Vin(low)= 0–1.5 V, Vin(high)= 3–25 V |
Digital Output Purpose | Programmatically set; fault (NC) |
Digital Outputs | 3x opto-isolated, 0–48 V DC, max. 350 mA; solid-state opto relay; 1x dedicated as Fault output (NC) |
Encoding | GVSP video streaming: uncompressed GVSP radiometric streaming: temperature linear and FLIR radiometric |
Ethernet Interface | Wired, Wi-Fi (optional) |
WiFi | Optional feature purchased separately. RP-SMA, female connector |
EMC |
|
f-number | 1.4 |
Image Frequency | 30 Hz |
Thermal Sensitivity/NETD | <35 mK |
Accuracy | ±2°C (±3.6°F) or ±2% of reading, for ambient temperature 15°C–35°C (59°F–95°F) and object temperature above 0°C (32°F) |
Alarm Functions | NA |
Alarm Output | NA |
Communication & Data Storage | |
Digital I/O connector type | M12 12-pin A-coded, Male (shared with external power) |
Digital I/O isolation voltage | 500 VRMS |
Digital input purpose |
NUC; NUC disable; image TAG (Start, Stop, General); image flow control (acc. SFNC 2.3):
|
Digital Inputs | 2x opto-isolated, Vin(low)= 0–1.5 V, Vin(high)= 3–25 V |
Digital Output Purpose | Programmatically set; fault (NC) |
Digital Outputs | 3x opto-isolated, 0–48 V DC, max. 350 mA; solid-state opto relay; 1x dedicated as Fault output (NC) |
Encoding | GVSP video streaming: uncompressed GVSP radiometric streaming: temperature linear and FLIR radiometric |
Ethernet | For control, result, image, and power |
Ethernet Communication |
|
Ethernet Connector Type | M12 8-pin X-coded, female; RP-SMA, female |
Ethernet Interface | Wired, Wi-Fi (optional) |
Ethernet Power | Power over Ethernet, PoE IEEE 802.3af class 3 |
Ethernet Protocols |
|
Ethernet Standard | IEEE 802.3 |
Ethernet Type | 1000 Mbps |
Image Storage | NA |
Multicast | Yes |
RS-232 | M8 A-coded, male connector |
WiFi | Optional feature purchased separately. RP-SMA, female connector |
Imaging & Optical | |
Contrast Enhancement | FSX® / Histogram equalization (IR only) |
Detector Pitch | 17 µm |
Field of view (FOV) | Lens Dependent |
f-number | 1.4 |
Focal Length | Lens Dependent |
Focal Plane Array (FPA) | Uncooled microbolometer |
Focus | Fixed, adjustable with included tool |
Image Frequency | 30 Hz |
IR Resolution | 464 × 348 |
Minimum Focus Distance | 0.25 m (0.82 ft) |
MSX | Yes, included in visual camera option |
Overlay | Without |
Radiometric IR video streaming | GigE Vision |
Readout | No measurements readouts, only streamed video |
Spectral Range | 7.5–14 µm |
Streaming Resolution | GVSP video streaming: 640 × 480 pixels GVSP radiometric streaming: 464 × 348 pixels |
Thermal Sensitivity/NETD | <35 mK |
Video Streaming | GVSP (GigE Vision) protocol |
Visible Camera | Optional accessory |
Measurement & Analysis | |
Accuracy | ±2°C (±3.6°F) or ±2% of reading, for ambient temperature 15°C–35°C (59°F–95°F) and object temperature above 0°C (32°F) |
Alarm Functions | NA |
Alarm Output | NA |
Atmospheric transmission correction | Based on inputs of distance, atmospheric temperature, and relative humidity |
Automatic hot & cold detection | NA |
Measurement Corrections | NA |
Measurement Presets | NA |
Measurement Tools | NA |
Object Temperature Range | –20 to 175°C (–4 to 347°F) 175 to 1000°C (347 to 1832°F) |
General | |
Base Mounting | 4 x M2.5 direct into camera or 4x 10-32 UNF onto bottom cooling plate |
Housing material | Aluminium |
Size (L x W x H) | 107 × 67 × 57 mm (4.21 × 2.64 × 2.24 in) |
Weight | 519 g (1.14 lb) without bottom cooling plate |
Environmental & Certifications | |
Corrosion |
|
EMC |
|
Encapsulation | IEC 60529 and IP66 |
Humidity (Operating and Storage) | IEC 60068-2-30/24 hours, 95% relative humidity, 25–40°C (77–104°F)/2 cycles EN60068-2-38 |
Operating Temperature Range | –20 to 50°C (–4 to 122°F) Bottom cooling plate is needed in temperatures above 40°C (104°F). Maximum internal temperature sensor: 70°C (158°F) |
Radio Spectrum |
|
Shock | IEC 60068-2-27, 25 g |
Tripod Mounting | 4 x M2.5 direct into camera or 4x 10-32 UNF onto bottom cooling plate |
Vibration |
|
Power | |
External Power Operation | 24/48 V DC 8 W max |
External Voltage | Allowed range 18–56 V DC |
Power Connection | M12 12-pin A-coded, male (shared with Digital I/O) |
Power Consumption |
|
User Interface | |
Web interface | Yes |