All FLIR Products

Teledyne FLIR A50 Advanced Smart Sensor Automation Thermal Camera – Choice of Lens

SKU
A50-SS
Rating:
0%
(0)
Reward Points
:
11000
£11,000.40 £9,167.00
Free UK Delivery*
Advice & Support Call 01642 931329 or contact us
Price Match We won't be beaten, let us know
Teledyne FLIR A50 Advanced Smart Sensor Automation Thermal Camera – Choice of Lens

The Teledyne FLIR A50 Advanced Smart Sensor Automation Thermal Camera is an infrared-imaging automation camera with an advanced smart sensor configuration, built-in analytics, and onboard alarms. Suitable for condition monitoring and early fire detection, the Teledyne FLIR A50 Advanced Smart Sensor Automation Thermal Camera delivers detailed, low-noise thermal imaging with integrated temperature data. To this end, it offers a 464 x 348px IR resolution and can measure temperatures between -20°C and +1000°C to an accuracy of ±2°C/2%. Exact temperature data can be extracted from each pixel using FLIR’s Atlas SDK. Featuring thermal sensors that communicate with standard industrial protocols, the Teledyne FLIR A50 Advanced Smart Sensor Automation Thermal Camera is easily integrated into video management systems and HMI and SCADA systems. It also supports simple configuration via a web browser and includes an SNMP trap and advanced firewall protection allowing multiple network devices to work together securely. Lightweight, durable (IP66), compact and equipped with heavy-duty M8/12 connectors, the Teledyne FLIR A50 Advanced Smart Sensor Automation Thermal Camera is compatible with an array of mounting options and can be installed in a variety of demanding settings. The Teledyne FLIR A50 Advanced Smart Sensor Automation Thermal Camera is a compact, configurable temperature-measuring thermal camera perfect for protecting assets, improving safety, maximising uptime, and minimising maintenance costs.

Teledyne FLIR A50 Advanced Smart Sensor Automation Thermal Camera Key Features

  • Thermal imaging automation camera with an advanced smart sensor configuration
  • Built-in analytics
  • Onboard alarms
  • Available with a selection of lenses and optional extras
  • Suitable for condition monitoring
  • Suitable for early fire detection
  • Delivers detailed, low-noise thermal imaging with integrated temperature data
  • IR resolution: 464 x 348px
  • Total temperature range: -20°C to +1000°C
  • Approximate accuracy: ±2°C/2%
  • Extract temperature data using FLIR’s Atlas SDK
  • Supports optional MSX imaging
  • Optional built-in visual camera
  • Thermal sensors communicate with standard industrial protocols
  • Simply integrates into video management systems
  • Easily integrates into HMI and SCADA systems
  • Supports simple configuration via a standard web browser
  • SNMP trap
  • Advanced firewall protection
  • Optional ONVIF S compatibility
  • Lightweight
  • Durable (IP66)
  • Compatible with an array of mounting options
  • Heavy-duty M8/12 connectors
  • A compact, configurable temperature-measuring thermal camera
  • Protect assets
  • Improve safety
  • Maximise uptime
  • Minimise maintenance costs

What’s Included?

  • Teledyne FLIR A50 Advanced Smart Sensor Automation Thermal Camera
  • Your Choice of Lens

Teledyne FLIR A50 Advanced Smart Sensor Automation Thermal Camera Technical Specifications 

Digital I/O connector type M12 12-pin A-coded, Male (shared with external power)
Digital Inputs 2x opto-isolated, Vin(low)= 0–1.5 V, Vin(high)= 3–25 V
Digital Output Purpose
  • As a function of alarm, output to external device
  • Fault (NC)
Digital Outputs 3x opto-isolated, 0–48 V DC, max. 350 mA; solid-state opto relay; 1x dedicated as Fault output (NC)
Encoding Video stream: H.264, MPEG4, or MJPEG
Radiometric stream: Compressed JPEG-LS, FLIR radiometric
Ethernet Interface Wired, Wi-Fi (optional)
WiFi Optional feature purchased separately. RP-SMA, female connector
EMC
  • ETSI EN 301 489-1 (radio)
  • ETSI EN 301 489-17 (radio)
  • EN 61000-4-8 (magnetic field)
  • FCC 47 CFR Part 15 Class B (emission US)
  • ISO 13766-1 (EMC - Earth-moving and building construction machinery)
  • EN ISO 14982 (EMC - Agricultural and forestry machinery)
f-number 1.4
Image Frequency 30 Hz
Thermal Sensitivity/NETD <35 mK
Accuracy ±2°C (±3.6°F) or ±2% of reading, for ambient temperature 15°C–35°C (59°F–95°F) and object temperature above 0°C (32°F)
Alarm Functions 10 Spotmeters 10 Boxes and Mask polygons (total number) 3 Deltas (difference any value/reference/external lock) 2 Isotherm (above/below/interval) 2 Iso-coverage 1 Reference temperature 2 Lines 1 Polyline
Alarm Output Digital out E-mail (SMTP) (push) EtherNet/IP (pull) File transfer (FTP) (push) Modbus TCP Client (push) Modbus TCP Server (pull) MQTT (push) ONVIF events (push) Query over RESTful API (pull) Store image or video
Communication & Data Storage 
Digital I/O connector type M12 12-pin A-coded, Male (shared with external power)
Digital I/O isolation voltage 500 VRMS
Digital input purpose NUC, NUC disable, alarm
Digital Inputs 2x opto-isolated, Vin(low)= 0–1.5 V, Vin(high)= 3–25 V
Digital Output Purpose
  • As a function of alarm, output to external device
  • Fault (NC)
Digital Outputs 3x opto-isolated, 0–48 V DC, max. 350 mA; solid-state opto relay; 1x dedicated as Fault output (NC)
Encoding Video stream: H.264, MPEG4, or MJPEG
Radiometric stream: Compressed JPEG-LS, FLIR radiometric
Ethernet For control, result, image, and power
Ethernet Communication TCP/IP socket-based FLIR proprietary
Ethernet Connector Type M12 8-pin X-coded, female; RP-SMA, female
Ethernet Interface Wired, Wi-Fi (optional)
Ethernet Power Power over Ethernet, PoE IEEE 802.3af class 3
Ethernet Protocols
  • EtherNet/IP
  • IEEE 1588
  • Modbus TCP
  • MQTT
  • SNMP
  • TCP, UDP, SNTP, RTSP, RTP, HTTP, HTTPS, ICMP, IGMP, sftp (server), FTP (client), SMTP, DHCP, MDNS (Bonjour), uPnP
Ethernet Standard IEEE 802.3
Ethernet Type 1000 Mbps
Image Storage NA
Multicast Yes
RS-232 M8 A-coded, male connector
WiFi Optional feature purchased separately. RP-SMA, female connector
Imaging & Optical 
Contrast Enhancement FSX® / Histogram equalization (IR only)
Detector Pitch 17 µm
Field of view (FOV) Lens dependent 
f-number 1.4
Focal Length 4.1 mm (0.16 in)
Focal Plane Array (FPA) Uncooled microbolometer
Focus Fixed, adjustable with included tool
Image Frequency 30 Hz
IR Resolution 464 × 348
Minimum Focus Distance 0.1 m (0.33 ft)
MSX Yes, included in visual camera option
Overlay Without
Radiometric IR video streaming RTSP protocol
Readout No measurements readouts, only streamed video
Spectral Range 7.5–14 µm
Streaming Resolution RTSP Video stream 0: 640 × 480 pixels RTSP Video stream 1: 1280 × 960 pixels Radiometric stream: 464 × 348 pixels
Thermal Sensitivity/NETD <35 mK
Video Streaming RTSP protocol
Visible Camera Optional accessory
Measurement & Analysis 
Accuracy ±2°C (±3.6°F) or ±2% of reading, for ambient temperature 15°C–35°C (59°F–95°F) and object temperature above 0°C (32°F)
Alarm Functions 10 Spotmeters 10 Boxes and Mask polygons (total number) 3 Deltas (difference any value/reference/external lock) 2 Isotherm (above/below/interval) 2 Iso-coverage 1 Reference temperature 2 Lines 1 Polyline
Alarm Output Digital out E-mail (SMTP) (push) EtherNet/IP (pull) File transfer (FTP) (push) Modbus TCP Client (push) Modbus TCP Server (pull) MQTT (push) ONVIF events (push) Query over RESTful API (pull) Store image or video
Atmospheric transmission correction Based on inputs of distance, atmospheric temperature, and relative humidity
Automatic hot & cold detection Max./min. temperature value and position shown within Box
Measurement Corrections Global object parameters; local parameters per analyze function; external Black-body correction
Measurement Presets Yes
Measurement Tools 10 spotmeters, 10 boxes and mask polygons (total number), 3 Deltas (difference any value/reference/external lock), 2 isotherms (above/below/interval), 2 iso-coverage, 1 reference temperature, 2 lines, 1 polyline
Object Temperature Range –20 to 175°C (–4 to 347°F) 175 to 1000°C (347 to 1832°F)
General
Base Mounting 4 x M2.5 direct into camera or 4x 10-32 UNF onto bottom cooling plate
Housing material Aluminium
Size (L x W x H) 107 × 67 × 57 mm (4.21 × 2.64 × 2.24 in)
Weight 519g (1.14lb) without bottom cooling plate
Environmental & Certifications  
Corrosion
  • ISO 12944 C4 G or H
  • EN60068-2-11
EMC
  • ETSI EN 301 489-1 (radio)
  • ETSI EN 301 489-17 (radio)
  • EN 61000-4-8 (magnetic field)
  • FCC 47 CFR Part 15 Class B (emission US)
  • ISO 13766-1 (EMC - Earth-moving and building construction machinery)
  • EN ISO 14982 (EMC - Agricultural and forestry machinery)
Encapsulation IEC 60529 and IP66
Humidity (Operating and Storage) IEC 60068-2-30/24 hours, 95% relative humidity, 25–40°C (77–104°F)/2 cycles EN60068-2-38
Operating Temperature Range –20 to 50°C (–4 to 122°F) Bottom cooling plate is needed in temperatures above 40°C (104°F). Maximum internal temperature sensor: 70°C (158°F)
Radio Spectrum
  • FCC 47 CFR Part 15 Class C (2.4 GHz band US)
  • FCC 47 CFR Part 15 Class E (5 GHz band US)
  • RSS-247 (2.4 GHz and 5 GHz band Canada)
  • ETSI EN 300 328 V2.1.1 (2.4 GHz band EU)
  • ETSI EN 301 893 V2.1.1 (5 GHz band EU)
Shock IEC 60068-2-27, 25 g
Tripod Mounting 4 x M2.5 direct into camera or 4x 10-32 UNF onto bottom cooling plate
Vibration
  • IEC 60068-2-6, 0.15 mm at 10–58 Hz and 2 g at 58–500 Hz, sinusoidal
  • IEC 61373 Cat 1 (Railway)
Power 
External Power Operation 24/48 V DC 8 W max
External Voltage Allowed range 18–56 V DC
Power Connection M12 12-pin A-coded, male (shared with Digital I/O)
Power Consumption
  • 7.5 W at 24 V DC typical
  • 7.8 W at 48 V DC typical
  • 8.1 W at 48 V PoE typical
User Interface 
Web interface Yes
Teledyne FLIR A50 & A70 Advanced Smart Sensor Automation - Datasheet Datasheets FLIR A50/A70 Series User Manual Manuals & Guides Teledyne FLIR Smart Sensor Cameras - Comparison Chart Notes & Other

Reviews

Additional Information
SKU A50-SS